SWaP-C PRECISION TIMING Ultra-Low Power Oscillators (<60 mW) & Atomic Standards
North Andover, MA USA Tel: +1 (978) 406-7730 [email protected]
TimeCubic Inc.
← Back to Products / Model Q200

Model Q200 High Precision OCXO Satellite Disciplined Timing Receiver

Satellite / GPS Synchronized • 10 MHz Reference Clock • Low Phase Noise & Low Jitter • Radar & C-UAS on the Move

TimeCubic Model Q200

Technical Plots & Mechanical Drawings

Laboratory Characterization & Engineering Dimensions

Package Dimension

65.0 × 65.0 × 23.0 mm
Model Q200 Package Dimension

Bottom and side view mechanical outline & pin assignments

Short Term Hold Over

±1.0 μs / 24h
Model Q200 Short Term Hold Over

Short-term holdover & temperature excursion characterization

5 Day Holdover Accumulation Curves

5-Day Drift Plot
Model Q200 5 Day Holdover Accumulation Curves

Extended 5-day cumulative holdover phase error trajectory

Calnex Sentinel 1PPS TIE Measurement

<350 ns / 24h+
Calnex Sentinel 1PPS TIE Measurement over 24 hours

Real-time Calnex Sentinel sync analyzer log: 1PPS Time Interval Error (TIE) bounded within <350 ns over >24 hours (80,000+ s) holdover

30-Day Long-Term Aging & Disciplining Curve

AXTAL Lab Report
AXTAL 30-Day Long-Term Aging and Disciplining Stability Report

30-day continuous laboratory aging and holdover characterization demonstrating ultra-flat drift rate and sub-ppb long-term stability

Core Architectural Highlights

✓
High Precision OCXO Disciplining

Disciplines to 1 ns RMS phase and <1×10-12 in frequency from satellite timing receivers with sub-picosecond low jitter.

✓
Radar & C-UAS Holdover Synchronization

Maintains ±1.0 μs / 24-hour holdover over ±5°C ambient temperature swings for Radar, C-UAS, and tactical vehicles on the move.

✓
Low Phase Noise Multi-Outputs

Low phase noise OCXO clocking with 10 MHz reference, 5 MHz, 8.192 MHz, and synchronized 1PPS outputs.

✓
Serial Telemetry & ToD

Integrated RS232 serial telemetry reporting 1-second phase resolution (≤1 ns) and Time of Day.

Technical Specifications (Rev J Standard)

Supply Voltage +5.0V DC (±5%)
Steady-State Power 3.0 W typ @ 25°C
Warm-Up Power & Time 9.0 W max (5 min to within ±5 ppb)
Disciplined Accuracy <1×10-12 Frequency • 1 ns RMS Phase to GNSS
24-Hour Holdover (Code 10) ±1.0 μs / 24h (over ±5°C temperature variation)
24-Hour Holdover (Std 15) ±1.5 μs / 24h (over ±5°C temperature variation)
Clock Outputs 10 MHz standard (5 MHz and 8.192 MHz available)
Operating Temperature -10°C to +70°C (Code A) / -20°C to +70°C (Code B)
Digital Communications RS232 (57600 baud, 8-N-1) • Continuous 1-second phase report
Dimensions & Form Factor 65.0 × 65.0 × 23.0 mm (2.56 × 2.56 × 0.91 in) • 51x51mm opt.

Interface & Pin Assignment

Pin # Signal Type Description
1VCCPower+5.0V DC Main Power Supply Input
2GNDPowerCommon Ground & Chassis Shield
31PPS_INInputGNSS Receiver / Satellite Reference 1PPS Input
41PPS_OUTOutputDisciplined 1PPS Pulse Output (Jitter <1 ns RMS)
5RF_OUTOutput10 MHz Precision Reference Clock Output (HCMOS / Sine opt.)
6TXDOutputRS232 Serial Telemetry Data Output (ToD & Phase)
7RXDInputRS232 Serial Configuration Command Input
8LOCK_INDOutputDiscipline Lock Status (High = Synchronized & Locked)

Model Q200 Engineering FAQ

How does Model Q200 protect smart grid PMUs against GNSS jamming? ↓
When GNSS is active, Model Q200 continuously trains an adaptive Kalman filter on internal temperature excursions and crystal aging. During jamming or spoofing attacks, it activates proprietary holdover algorithms, maintaining ±1.0 μs timing error over 24 hours (±5°C variation), keeping PMUs fully compliant with IEEE C37.118 TVE < 1%.
What simultaneous frequency outputs are available? ↓
Model Q200 outputs a primary 10 MHz reference clock alongside a synchronized 1PPS pulse (<1 ns RMS jitter). Custom firmware options provide simultaneous 5 MHz and 8.192 MHz auxiliary outputs to drive legacy telecom and power substation architectures.

Model Q200 Inquiries

Contact our North Andover engineering lab for lead times and pricing.

Request Evaluation Unit →